Hot spare drive protection, Automatically configuring hot spares – Dell PowerVault MD3000 User Manual

Page 58

Advertising
background image

58

Disk Groups and Virtual Disks

If you plan to create multiple virtual disks, wait until you have created all the

virtual disks to register them. Waiting prevents you from having to register

virtual disks more than once.

Linux

NOTE:

You need super-user (Linux) privileges to run the

hot_add

utility.

The hot_add utility is installed with the host-agent package and is run from

the Linux command line. You cannot run the hot_add utility using the MD

Storage Manager.

Windows

Windows automatically registers virtual disks.

NOTE:

Virtual disks mapped to Windows Server 2008 hosts are marked offline by

default. To bring the virtual disks online, use the Disk Management MMC (if you are

using a GUI version of Windows Server 2008) or use the DiskPart utility (if you are

using a Core version of Windows Server 2008).

Hot Spare Drive Protection

Hot spare drives in a storage array provide an additional level of protection in

case a physical disk fails. Hot spare drives only take over for failed drives in a

RAID level 1, 5, or 6 disk group. Using a hot spare drive can be an advantage

because it automatically replaces a failed physical disk that is part of a disk

group.
You can see whether hot spare protection is currently set by viewing the Hot

Spare Physical Disks line in the Hardware Components area of the Summary

tab. You can also see the number of standby and in-use hot spares. A standby

hot spare drive is a physical disk that has been assigned as a hot spare drive and

is available to take over for any failed physical disk. An in-use hot spare drive is

a physical disk that has been assigned as a hot spare drive and is currently

taking over for a failed physical disk.

Automatically Configuring Hot Spares

You can choose to allow MD Storage Manager to automatically configure hot

spare drives. With automatic configuration, the controller automatically

configures the number and type of hot spare drives that will provide optimal

Advertising