Operating Your Storage Enclosure
21
Figure 2-1.
Connecting a SAS Cable
NOTE:
In a unified-mode configuration, connect the host to the first EMM
module (EMM 0). See Figure 2-2. For unified-mode configurations utilizing 
redundant paths, connect the host to the second EMM module (EMM1). See 
Figure 2-3.
See your RAID controller documentation to ensure that the controller is 
properly installed.
•
If you are configuring your enclosure in a unified-mode configuration, 
connect the SAS cable from the host controller to the In port on the 
EMM module of the first enclosure in the daisy chain. See Figure 2-2. 
Attach subsequent storage enclosures in the daisy chain to the Out 
port on the first upchain storage enclosure. 
•
If you are configuring your enclosure in a split-mode configuration, 
attach the SAS cable from the first host controller to the In port on 
the primary EMM module and the SAS cable from the second host 
controller port to the In port on the secondary EMM. See Figure 2-4. 
NOTE:
In a split-mode configuration, you can cable the enclosure to operate
in either a two-host or single-host configuration.