Troubleshooting the installation – Cisco 10008 User Manual

Page 15

Advertising
background image

15

Cisco 10008 Router Performance Routing Engine 3 Installation

OL-8544-01

Installing or Replacing a PRE3

Step 2

Loosen the top and bottom captive screws (see

Figure 8

) on the PRE3.

Note

The top and bottom captive screws must be loosened prior to pivoting the ejector levers in

Step 3

.

Step 3

Simultaneously pivot both ejector levers (see

Figure 7

) away from each other to disengage the PRE3

from the backplane.

Step 4

Slide the PRE3 out of the slot (see

Figure 6

) and place it on an antistatic surface, or in an antistatic bag.

Step 5

See the

“Installing or Replacing a PRE3” section on page 11

for instructions on how to install a new

PRE3.

Note

If you are not installing a replacement PRE3, install a blank faceplate in the slot.

Warning

Do not operate the system unless all slots contain a PRE3, line card, or a blank faceplate. Blank
faceplates are necessary in empty slots to prevent exposure to hazardous voltages, to reduce
electromagnetic interference (EMI) that may disrupt other equipment, and to direct the flow of cooling
air through the chassis.

Step 6

Power on the system if you have powered it off.

Troubleshooting the Installation

Refer to

Figure 2

and

Table 1

for descriptions of the LEDs on the PRE3. Follow the instructions in

Table 4

to troubleshoot the installation.

Table 4

PRE3 Installation Troubleshooting

Symptom

Possible Cause

Corrective Action

PEMs, fans, and other line cards
do not operate

1.

Disconnected power cord.

2.

Power switch is in the Off
position.

3.

The PRE3 fuses are blown.

1.

Check that all power cords
are properly connected to
both the chassis and at the
power connection end.

2.

Set the PEM power
switches to the On
position.

3.

Replace the PRE3.

Advertising