Forcing failover in a redundant pair, Managing system boot parameters – Cisco 10008 User Manual

Page 16

Advertising
background image

16

Cisco 10008 Router Performance Routing Engine 3 Installation

OL-8544-01

Forcing Failover in a Redundant Pair

If these troubleshooting procedures do not correct the problem, refer to the

Cisco 10000 Series Router

Troubleshooting Guide

for additional information.

Forcing Failover in a Redundant Pair

To manually force the active and standby devices in a redundant pair to failover, use the redundancy
force-failover
command. Manually force the active and standby PRE3s to reverse roles if you need to
replace the active one. You can then replace the PRE3 while causing only minimal disruption of traffic.

The following example shows how to set the standby PRE3 to be active:

Router# redundancy force-failover main-cpu

This command does not generate an alarm.

Managing System Boot Parameters

During the boot process, the system reads a software configuration register that defines certain system
parameters. The software configuration register is a 16-bit register in NVRAM used to define such
characteristics as:

The source of the Cisco IOS software image required to run the router

Whether the system software should ignore the contents of NVRAM

The behavior of the Break function

By modifying the boot parameters, you can customize your Cisco 10008 router. For example, a common
configuration register setting in some lab environments is 0x2100. Using this setting, the system boots
to the ROM monitor (ROMmon) prompt, where a technician can load a specific image by entering the
boot command at the ROMmon prompt.

The FAIL LED does not light
during the power-on self-test

1.

The PRE3 is not properly
seated.

2.

Bad PRE3 slot or backplane
connector.

1.

Be sure the ejector levers
are fully closed and that
the captive screws have
been tightened.

2.

Remove the PRE3 and
install it in another PRE3
slot.

PRE3 does not operate properly

1.

Bad PRE3 slot or backplane
connector.

2.

Bad PRE3.

1.

Remove the PRE3 and
install it in another PRE3
slot.

2.

Replace the PRE3.

Symptom

Possible Cause

Corrective Action