Features, General features – Dell PowerEdge RAID Controller S300 User Manual

Page 21

Advertising
background image

Features

21

3

Features

General Features

The features of the Dell PowerEdge RAID Controller (PERC) S100 and

PERC S300 adapter are described in Table 3-1.

NOTE:

BAS, BGI, CC and OCE run only on the operating system.

Table 3-1. Features of the PERC S100 controller and PERC S300 controller

RAID Controller Feature Description
Automatic virtual disk

rebuild

Rebuilds a redundant virtual disk automatically when a

failure is detected, if a hot spare is assigned for this capability.

Background Array

Scan (BAS)

Verifies and corrects correctable media errors on mirror,

volume, or parity data for virtual disks. BAS starts

automatically after a Virtual Disk is created while in the OS.

Background virtual

disk initialization

(BGI)

The background initialization of a redundant virtual disk

creates the parity data that allows the virtual disk to maintain

its redundant data and survive a physical disk failure.
Because background initialization helps the controller to

identify and correct problems that might occur with the

redundant data at a later time, background initialization is

similar to a consistency check.
Background initialization allows a redundant virtual disk to

be used immediately. Data is lost if a physical disk fails before

the completion of a BGI.

NOTE:

Although a BGI is software-initiated at the PERC Virtual

Disk Management utility, the PERC S100 adapter/PERC S300

adapter drivers must be loaded before the BGI runs.

NOTE:

Unless mentioned otherwise, the term PERC Virtual Disk

Management utility refers to both the PERC S100 Virtual Disk

Management utility and the PERC S300 Virtual Disk

Management utility.

A5_bk0.book Page 21 Thursday, February 10, 2011 8:34 PM