Hardware Installation

35

Connect Physical Disks to the PERC S300 Adapter

WARNING:

Critical system components might be damaged if the installer is not

properly grounded to prevent electrostatic discharge (ESD).

NOTE:

Use either the standard power connector or, if available on the power

supply, a SATA/SATA II power connector. Do not use both.

NOTE:

You can view the physical disk LEDs on a system that uses a PERC S300

controller by removing the front panel from the system.

NOTE:

The controller supports a feature that staggers the spinup of each physical

disk sequentially. This allows enough time between physical disk starts to prevent

the power supply from overloading.

1 Install the physical disks into the system.
2 Connect a multiple-connector cable from the physical disks (or from the

backplane) to the controller.

NOTE:

If the system contains a PERC S300 controller and has a backplane with hot-

swap capability, the cables cannot be inserted directly into the physical disks. The

physical disks (within their carriers) are inserted and seated in the backplane.

A cable from the backplane is then connected to the PERC S300 controller.

Complete the Hardware Installation

After the controller and cables are installed, perform the following steps:

1 Make sure that the wire bundles and cables inside the system are not

twisted. Make sure they do not interfere with fans, power supplies, heat

sinks, or electrical devices.

2 Replace the cover of the system. See your system’s Hardware Owner’s

Manual or User’s Guide for more information on closing the system.

3 Reconnect the power cable(s) and network cables, and then turn on the

system.

A5_bk0.book Page 35 Thursday, February 10, 2011 8:34 PM