Physical disk-related errors, Table 7-13. the physical disk fails, Table 7-14. a dedicated hot spare fails – Dell PowerEdge RAID Controller S300 User Manual

Page 75

Advertising
background image

Troubleshooting

75

Physical Disk-Related Errors

Table 7-13. The Physical Disk Fails

Likely Causes to Check

Corrective Actions

A physical disk is not visible

in the PERC Virtual Disk

Management utility or is

offline

• Check that the cables are properly connected.
• For PERC S300 adapters only: check that the physical

disk is installed properly in the system’s backplane.

• For PERC S300 adapters only: check the system’s

backplane for damage.

• For PERC S300 adapters only: reinstall the physical

disk and make sure that it is seated correctly in the

system’s backplane.

• Perform a Rescan, to (a) update the status of storage

devices attached to the controller, or (b) fix an error

caused by deleting or initializing a virtual disk.

A physical disk is highlighted

red at the PERC Virtual Disk

Management utility

• Replace the physical disk. Depending on the

RAID level of the virtual disk, data might be lost.

• Perform a rescan to confirm that the new disk was

discovered.

Table 7-14. A Dedicated Hot Spare Fails

Likely Causes to Check

Corrective Actions

The controller cannot

communicate with the hot

spare

• Check that the cable from the controller to the

physical disk is connected properly.

• Make sure that the physical disk is still assigned as a

global or dedicated hot spare.

• Check if the physical disk assigned as the hot spare

has failed.

The dedicated spare is not

visible in the PERC Virtual

Disk Management utility or

is offline

The controller cannot communicate with the hot

spare.

• Check if the physical disk has been removed or has

failed.

• Check for a loose or bad cable.

A5_bk0.book Page 75 Thursday, February 10, 2011 8:34 PM