Microprocessor/airflow shroud/heat sink assembly – Dell OptiPlex GX200 User Manual

Page 56

Advertising
background image

Figure 29. RIMM Removal

To reinstall a RIMM, perform the following steps:

1. Locate the plastic securing clips at each end of the socket (see

Figure 30

).

2. Press the clips outward until they snap open.

3. Press the RIMM straight into the slot running down the center of the socket until the securing tabs snap into place around the ends of the

RIMM.

4.

Replace the computer cover

and

reset the chassis intrusion detector

.

Figure 30. RIMM Installation

Microprocessor/Airflow Shroud/Heat Sink Assembly

To replace a microprocessor, perform the following steps:

1.

Remove the computer cover

.

2. Rotate the power supply up until it locks (see

Figure 20

).

3. Pull up on the airflow shroud release tabs while you lift and rotate the bottom of the shroud up and away from the back of the chassis and

microprocessor/heat sink assembly.

Figure 31. Microprocessor/Airflow Shroud/Heat Sink Removal

1 Securing clips (2)

1 Securing clips (2)

2 Notches (2)

CAUTION: The microprocessor SEC cartridge/heat sink assembly can get extremely hot. Be sure that the assembly has had
sufficient time to cool before you touch it.

NOTE: Dell recommends that only a technically knowledgeable person perform this procedure.