Memory double word logic

failure at address, read

value expecting value

 

Memory odd/even logic

failure at start address

to end address

 

Memory write/read failure

at address, read value

expecting value

 

Memory allocation error

 

Faulty application program.

 

Restart the application program.

 

Memory bank population

error!

 

Memory modules are not

installed in identical pairs;
faulty memory module(s).

 

Ensure that the memory modules are properly installed. See "

Memory Module Installation

Guidelines

" in "Installing System Components." If the problem persists, see "

Troubleshooting

System Memory

" in "Troubleshooting Your System."

 

Memory parity interrupt

at address

 

Faulty or improperly installed

memory modules.

 

Ensure that all memory modules are properly installed. See "

Memory Module Installation

Guidelines

" in "Installing System Components." If the problem persists, see "

Troubleshooting

System Memory

" in "Troubleshooting Your System."

 

Memory tests terminated

by keystroke

 

The spacebar was pressed

during POST to terminate the
memory test.

 

Information only.

 

No boot device available

 

Faulty or missing diskette or

CD drive subsystem, hard
drive, or hard-drive
subsystem.

 

 

Check the Integrated Devices configuration settings in the System Setup program. See "Using

the System Setup Program" in your User's Guide. Ensure that either SCSI Controller, Diskette
Controller
, or Integrated Drive Controller is enabled. If the system is booting from a SCSI
controller, ensure that the controller is properly connected. If the problem persists, replace the
diskette/CD drive subsystem. See "

Removing the Optional Diskette Drive

" in "Installing Drives."

If the problem persists, replace the faulty hard drive. See "

Hard Drives

" in "Installing Drives."

 

No boot sector on hard-

disk drive

 

An operating system is not

on the hard drive.

 

Check the hard drive configuration settings in the System Setup program. See "Using the

System Setup Program" in your User's Guide.

 

No timer tick interrupt

 

Faulty system board.

 

See "

Getting Help

."

 

Non-system disk or disk

error

 

Faulty diskette, diskette/CD-

drive assembly, hard drive, or
hard-drive subsystem; no
operating system on diskette
or hard drive.

 

Use a bootable diskette. If the problem persists, see "

Troubleshooting the Diskette Drive

,"

"

Troubleshooting the CD Drive

," "

Troubleshooting a SATA Hard Drive

," or "

Troubleshooting a

SCSI Hard Drive

," in "Troubleshooting Your System" for the appropriate drive(s) installed in your

system.

 

Not a boot diskette

 

Not a bootable diskette.

 

Use a bootable diskette.

 

PCI BIOS failed to

install

 

Loose cables to expansion

card(s); faulty or improperly
installed expansion card.

 

Ensure that all appropriate cables are securely connected to the expansion cards. See

"

Troubleshooting Expansion Cards

," in "Troubleshooting Your System."

 

Plug & Play Configuration

Error

 

Error encountered in

initializing PCI device; faulty
system board.

 

Install the NVRAM_CLR jumper and reboot the system. See

Figure A

-2

for jumper location.

Check for a BIOS update. If the problem persists, see "

Troubleshooting Expansion Cards

," in

"Troubleshooting Your System." If the problem persists, see "

Troubleshooting the System

Board

."

 

Primary drive n

configuration error

 

Primary drive n failure

 

Faulty or improperly installed

hard drive.

 

Ensure that the CD drive cables are properly connected. See "

Troubleshooting the CD Drive

."

 

Read fault

 

Requested sector not

found

 

Faulty diskette, diskette

drive, CD drive, or hard drive.

 

Replace the diskette. Ensure that the diskette, CD, and hard drive cables are properly

connected. See "

Troubleshooting the Diskette Drive

," "

Troubleshooting the CD Drive

,"

"

Troubleshooting a SATA Hard Drive

," or "

Troubleshooting a SCSI Hard Drive

," in

"Troubleshooting Your System" for the appropriate drive(s) installed in your system.

 

Reset failed

 

Improperly connected drive

interface or power cable.

 

Ensure that the interface and power cables are securely connected. See "

Troubleshooting the

Diskette Drive

" and "

Troubleshooting the CD Drive

," in "Troubleshooting Your System."