Quantum <Product Name>: <Part Name> Replacement
6-68170-01 Rev A
May 2014

2

Installing a 14U Library in a Rack

4 For the procedure “Preparing Modules for Rack Installation”, follow these

steps:

a Remove all tape drives, power supplies, and all cords and cables from

the library modules. The modules are much easier to lift into the rack

without the additional weight of the tape drives.

WARNING: Without tape drives, tape cartridges, or power supplies, a 5U

Library Control Module weighs approximately 60 lbs (27.2 kg). A

9U Library Expansion Module, without tape drives, tape

cartridges, or power supplies, exceeds 65 lbs (29.5 kg).

To avoid serious injury, at least two people are required to safely

lift the modules.

b Do not remove the orange shipping restraint from the robot.

5 Follow the instructions for “Installing the Bottom Module in the Rack” in the

User’s Guide with the assembled 14U library. Do not take apart the 5U and

9U modules for this procedure. Follow the next step before powering on the

library.

6 Ensure the library is secured properly and the installation in the rack is

complete.

Remove all shipping restraints before powering up the

library

.