Device n Frame Number Register [R]

• Device 1 Frame Number Register 0xC092

• Device 2 Frame Number Register 0xC0B2

Figure 38. Device n Frame Number Register

Register Description

The Device n Frame Number register is a read only register
that contains the Frame number of the last SOF packet
received. This register also contains a count of SOF/EOP
Timeout occurrences.

SOF/EOP Timeout Flag (Bit 15)

The SOF/EOP Timeout Flag bit indicates when an SOF/EOP
Timeout Interrupt occurs.

1: An SOF/EOP Timeout interrupt occurred

0: An SOF/EOP Timeout interrupt did not occur

SOF/EOP Timeout Interrupt Counter (Bits [14:12])

The SOF/EOP Timeout Interrupt Counter field increments by
1 from 0 to 7 for each SOF/EOP Timeout Interrupt. This field
resets to 0 when a SOF/EOP is received. This field is only
updated when the SOF/EOP Timeout Interrupt Enable bit in
the Device n Interrupt Enable register is set.

Frame (Bits [10:0])

The Frame field contains the frame number from the last
received SOF packet in full speed mode. This field has no
function for low-speed mode. If a SOF Timeout occurs, this
field contains the last received Frame number.

Device n SOF/EOP Count Register [W]

• Device 1 SOF/EOP Count Register 0xC094

• Device 2 SOF/EOP Count Register 0xC0B4

Figure 39. Device n SOF/EOP Count Register

Register Description

The Device n SOF/EOP Count register must be written with
the time expected between receiving a SOF/EOPs. If the
SOF/EOP counter expires before an SOF/EOP is received, an
SOF/EOP Timeout Interrupt can be generated. The SOF/EOP
Timeout Interrupt Enable and SOF/EOP Timeout Interrupt
Flag are located in the Device n Interrupt Enable and Status
registers, respectively.

The SOF/EOP count must be set slightly greater than the
expected SOF/EOP interval. The SOF/EOP counter decre-
ments at a 12-MHz rate. Therefore in the case of an expected

1-ms SOF/EOP interval, the SOF/EOP count must be set
slightly greater then 0x2EE0.

Count (Bits [13:0])

The Count field contains the current value of the SOF/EOP
down counter. At power-up and reset, this value is set to
0x2EE0 and for expected 1-ms SOF/EOP intervals, this
SOF/EOP count should be increased slightly.

Reserved

All reserved bits must be written as ‘0’.

Bit #

15

14

13

12

11

10

9

8

Field

SOF/EOP

Timeout Flag

SOF/EOP

Timeout Interrupt Counter

Reserved

Frame...

Read/Write

R

R

R

R

-

R

R

R

Default

0

0

0

0

0

0

0

0

Bit #

7

6

5

4

3

2

1

0

Field

...Frame

Read/Write

R

R

R

R

R

R

R

R

Default

0

0

0

0

0

0

0

0

Bit #

15

14

13

12

11

10

9

8

Field

Reserved

Count...

Read/Write

-

-

R

R

R

R

R

R

Default

0

0

1

0

1

1

1

0

Bit #

7

6

5

4

3

2

1

0

Field

...Count

Read/Write

R

R

R

R

R

R

R

R

Default

1

1

1

0

0

0

0

0

[+] Feedback

Advertising