Spi control register [0xc0ca] [r/w – Cypress EZ-OTG CY7C67200 User Manual

Page 55

Advertising
background image

CY7C67200

Document #: 38-08014 Rev. *G

Page 55 of 78

SPI Control Register [0xC0CA] [R/W]

Figure 62. SPI Control Register

Register Description

The SPI Control register controls the SPI port. Fields apply to
both master and slave mode unless otherwise noted.

SCK Strobe (Bit 15)

The SCK Strobe bit starts the SCK strobe at the selected
frequency and polarity (set in the SPI Configuration register),
but not phase. This bit feature can only be enabled when in
master mode and must be during a period of inactivity. This bit
is self-clearing.

1: SCK Strobe Enable

0: No Function

FIFO Init (Bit 14)

The FIFO Init bit initializes the FIFO and clear the FIFO Error
Status bit. This bit is self-clearing.

1: FIFO Init Enable

0: No Function

Byte Mode (Bit 13)

The Byte Mode bit selects between PIO (byte mode) and DMA
(block mode) operation.

1: Set PIO (byte mode) operation

0: Set DMA (block mode) operation

Full Duplex (Bit 12)

The Full Duplex bit selects between full-duplex and half-duplex
operation.

1: Enable full duplex. Full duplex is not allowed and will not set
if the 3Wire Enable bit of the SPI Configuration register is set
to ‘1’

0: Enable half-duplex operation

SS Manual (Bit 11)

The SS Manual bit activates or deactivates SS if the SS Delay
Select field of the SPI Control register is all zeros and is
configured as master interface. This field only applies to
master mode.

1: Activate SS, master drives SS line asserted LOW

0: Deactivate SS, master drives SS line deasserted HIGH

Read Enable (Bit 10)

The Read Enable bit initiates a read phase for a master mode
transfer or set the slave to receive (in slave mode).

1: Initiates a read phase for a master transfer or sets a slave
to receive. In master mode this bit is sticky and remains set
until the read transfer begins.

0: Initiates the write phase for slave operation

Transmit Ready (Bit 9)

The Transmit Ready bit is a read-only bit that indicates if the
transmit port is ready to empty and ready to be written.

1: Ready for data to be written to the port. The transmit FIFO
is not full.

0: Not ready for data to be written to the port

Receive Data Ready (Bit 8)

The Receive Data Ready bit is a read-only bit that indicates if
the receive port has data ready.

1: Receive port has data ready to read

0: Receive port does not have data ready

Transmit Empty (Bit 7)

The Transmit Empty bit is a read-only bit that indicates if the
transmit FIFO is empty.

1: Transmit FIFO is empty

0: Transmit FIFO is not empty

Receive Full (Bit 6)

The Receive Full bit is a read-only bit that indicates if the
receive FIFO is full.

1: Receive FIFO is full

0: Receive FIFO is not full

Transmit Bit Length (Bits [5:3])

The Transmit Bit Length field controls whether a full byte or
partial byte is to be transmitted. If Transmit Bit Length is ‘000’,
a full byte is transmitted. If Transmit Bit Length is ‘001’ to ‘111’,
the value indicates the number of bits that will be transmitted.

Bit #

15

14

13

12

11

10

9

8

Field

SCK

Strobe

FIFO

Init

Byte

Mode

Full Duplex

SS

Manual

Read

Enable

Transmit

Ready

Receive

Data Ready

Read/Write

W

W

R/W

R/W

R/w

R/W

R

R

Default

0

0

0

0

0

0

0

1

Bit #

7

6

5

4

3

2

1

0

Field

Transmit

Empty

Receive

Full

Transmit Bit Length

Receive Bit Length

Read/Write

R

R

R/W

R/W

R/W

R/W

R/w

R/W

Default

1

0

0

0

0

0

0

0

[+] Feedback

Advertising