Management issues, Desktop displays incorrect system information, 3 management issues – Dell PowerVault NX3100 User Manual

Page 13

Advertising
background image

3

Management Issues

The following section discusses various management issues.

Desktop Displays Incorrect System Information

Description

The information present on the desktop does not match the actual system information.
This issue occurs because the Dell Desktop System Information Utility does not refresh
automatically. If you make any changes while the system is running, the changes may not be
reflected in real time.

Workaround/
Solution

To workaround the issue, perform one of the following steps:

Log off and log on.

Run the Dell Desktop System Information Utility.

Reboot the system.

Insufficient Disk Space On A Volume Dedicated For iSCSI Virtual

Disk

Description

System runs out of disk space on a volume dedicated for an iSCSI virtual disk or device. System
displays a warning or a message that the system is running out of disk space on a newly created
volume for iSCSI LUN.

Workaround/
Solution

This message is for your information only.
The system ensures the .vhd file is the same size as the volume it resides on. This issue occurs due
to the Microsoft iSCSI software target architecture.
To find out the actual free space on the disk, view the capacity from the client connected to the disk.

Single Instance Storage (SIS) And File Server Resource Manager

(FSRM) Display Incorrect Disk Space

Description

If SIS is enabled on a volume, FSRM may incorrectly report the amount of disk space used on
that volume for a user.

Workaround/
Solution

This is a design characteristic of the operating system and occurs when the files are migrated to
the SIS common store.

13

Advertising