Dell PowerEdge M605 User Manual
Page 170

170
Installing Enclosure Components
NOTICE:
A Torx T15 driver is required for this procedure.
1 Press the system power switch to turn off the system. See "System Control
NOTICE:
To avoid damaging the modules, you must remove all the modules
installed in the enclosure before removing the front module cage assembly and
midplane.
NOTICE:
If you remove the chassis from the rack, you must remove all modules
before moving the chassis. Do not use the LCD display as a handle when moving the
chassis.
2 Remove all of the blades. See "Removing a Blade" on page 96.
3 Remove the power supply modules. See "Removing a Power Supply
4 Remove the fan modules. See "Removing a Fan Module" on page 161.
5 Remove the CMC module(s). See "Removing a CMC Module" on
6 Remove the iKVM module. See "Removing an iKVM Module" on
7 Remove the I/O modules. See "Removing an I/O Module" on page 166.
8 Remove the four screws securing the front module cage assembly to the
enclosure. See Figure 4-8.