About Your System

Slot Mezz2_Fabric_B and slot Mezz4_Fabric_B support Fabric B. If a card
is installed in both slots, both cards must be identical. They must also
match the fabric type of the I/O modules installed in I/O module bays B1
and B2.

PowerEdge M600 and M605

The half-height PowerEdge M600 and M605 blades support two mezzanine
cards:

Mezzanine card slot C supports Fabric C. This card must match the fabric
type of I/O modules installed in I/O module bays C1 and C2.

Mezzanine card slot B supports Fabric B. This card must match the fabric
type of I/O modules installed in I/O module bays B1 and B2.

See "I/O Module Mezzanine Cards" on page 123 for more information on
mezzanine cards.

Table 1-11 shows various supported combinations of mezzanine cards and I/O
modules.

Table 1-11.

Supported I/O Module Configurations

Fabric A

Fabric B
Mezzanine
Card

Fabric C
Mezzanine
Card

I/O Bay A1,
A2

I/O Bay B1,
B2

I/O Bay C1,
C2

Standard
Integrated
LOM NIC

none

none

Ethernet
switch
module or
pass-through
module

none

none

Standard
Integrated
LOM NIC

Ethernet
mezzanine
card

none

Ethernet
switch
module or
pass-through
module

Ethernet
switch
module or
pass-through
module

none

Standard
Integrated
LOM NIC

none

Infiniband
mezzanine
card

Ethernet
switch
module or
pass-through
module

none

Infiniband
switch
module