Dell PowerEdge M605 User Manual

Page 70

Advertising
background image

70

About Your System

Error: Memory

failure detected.

Memory size

reduced. Replace

the faulty DIMM as

soon as possible.

Faulty or improperly
seated memory modules.

See "Troubleshooting Blade
Memory" on page 191.

Error programming

flexAddress (MAC)

for

bus

,

device

,

function

.

FlexAddress (virtual
MAC) is not supported on
the specified device.

Information only

Error programming

flexAddress (iSCSI

MAC) for

bus

,

device

,

function

.

FlexAddress (virtual
MAC) is not supported on
the specified device.

Information only

Error resetting

NIC after

programming

flexAddress for

bus

,

device

,

function

.

FlexAddress (virtual
MAC) is not supported on
the specified device.

Information only

FBD training

error: The

following branch

has been disabled:

Branch

x

.

The specified branch
(channel pair) contains
DIMMs that are
incompatible with each
other.

Ensure that only Dell
qualified memory is used.
Dell recommends
purchasing memory upgrade
kits directly from
http://www.dell.com or your
Dell sales agent to ensure
compatibility.

Gate A20 failure.

Faulty keyboard controller
(faulty blade board).

See "Getting Help" on
page 217.

General failure.

Operating system
corrupted or improperly
installed.

Reinstall the operating
system.

Table 1-18.

Blade Messages (continued)

Message

Causes

Corrective Actions

Advertising