Dell PowerVault 770N (Deskside NAS Appliance) User Manual
Page 56
illustrate how to cable a SAN-attached cluster to the CX200 and CX400 storage systems,
respectively.
illustrates how to cable a SAN-attached cluster to a CX600 storage system.
Table 5-2. Storage System Cabling Description
Storage
System
SP Ports
Fiber Optic Cables
Required
Cabling Description
CX200
One port per storage
processor
2
Attach one cable from each storage processor port to the
Fibre Channel switch.
CX400
Two ports per storage
processor
4
CX600
Four ports per storage
processor
8
Cabling a SAN-Attached Cluster to a Dell | EMC CX200 Storage System
1. Connect cluster node 1 to the SAN.
a. Connect a cable from HBA0 to Fibre Channel switch 0 (sw0).
b. Connect a cable from HBA1 to Fibre Channel switch 1 (sw1).
for each cluster node.
3. Connect the storage system to the SAN.
a. Connect a cable from Fibre Channel switch 0 (sw0) to SP-B port FE A.
b. Connect a cable from Fibre Channel switch 1(sw1) to SP-A port FE A.
Figure 5-3. Cabling a SAN-Attached Cluster to the Dell | EMC CX200 DPE