Step 1, Step 2 – Dell PowerVault 770N (Deskside NAS Appliance) User Manual

Page 60

Advertising
background image

b. Connect a cable from Fibre Channel switch 0 (sw0) to SP-B port FE A.

Cabling Multiple SAN-Attached Clusters to the CX400 Storage System

1. In the first cluster, connect cluster node 1 to the SAN.

a. Connect a cable from HBA0 to Fibre Channel switch 0 (sw0).

b. Connect a cable from HBA1 to Fibre Channel switch 1 (sw1).

2. In the first cluster, repeat

step 1

for each node.

3. For each additional cluster, repeat

step 1

and

step 2

.

4. Connect the storage system to the SAN.

a. Connect a cable from Fibre Channel switch 0 (sw0) to SP-A port FE 0.

b. Connect a cable from Fibre Channel switch 0 (sw0) to SP-B port FE 1.

c. Connect a cable from Fibre Channel switch 1 (sw1) to SP-A port FE 1.

d. Connect a cable from Fibre Channel switch 0 (sw1) to SP-B port FE 0.

Cabling Multiple SAN-Attached Clusters to the CX600 Storage System

1. In the first cluster, connect cluster node 1 to the SAN.

a. Connect a cable from HBA0 to Fibre Channel switch 0 (sw0).

b. Connect a cable from HBA1 to Fibre Channel switch 1 (sw1).

2. In the first cluster, repeat

step 1

for each node.

3. For each additional cluster, repeat

step 1

and

step 2

.

4. Connect the storage system to the SAN.

a. Connect a cable from Fibre Channel switch 0 (sw0) to SP-A port 0.

b. Connect a cable from Fibre Channel switch 0 (sw0) to SP-A port 2.

c. Connect a cable from Fibre Channel switch 0 (sw0) to SP-B port 1.

d. Connect a cable from Fibre Channel switch 0 (sw0) to SP-B port 3.

e. Connect a cable from Fibre Channel switch 1 (sw1) to SP-A port 1.

f. Connect a cable from Fibre Channel switch 1 (sw1) to SP-A port 3.

g. Connect a cable from Fibre Channel switch 1 (sw1) to SP-B port 0.

h. Connect a cable from Fibre Channel switch 1 (sw1) to SP-B port 2.

Zoning Your Dell | EMC Storage System in a Switched Environment

Dell only supports single-initiator zoning for connecting NAS clusters to a Dell | EMC storage system in a switched

environment. When using EMC PowerPath, a separate zone is created from each HBA to the following hardware components:

Advertising