Dell OptiPlex Gxi User Manual

Page 107

Advertising
background image

ISA Configuration Utility Messages

B-3

The ICU has
successfully config-
ured all Plug and Play
cards in your system.
For the new
configuration to take
effect, save the con-
figuration, then
reboot your system.

The ICU has successfully
configured all of the Plug
and Play expansion cards
that were not configured by
the Configuration Manager.

To accept these settings, save the configuration
information into NVRAM by selecting

EXIT

from the File menu and then selecting

YES

to

save. You must reboot your system for these
settings to take effect.

The loaded card is not
a

category card. Press

OK to proceed.

The category you have
chosen is not the correct cat-
egory under which to add
this card.

Select

OK

. The ICU automatically opens the

correct category’s dialog box. Continue the pro-
cedure for adding the card as described in
“Adding a Listed Card” or “Adding an Unlisted
Card” in Chapter 3.

No more DMA values can
be added.

No more interrupt val-
ues can be added.

No more memory values
can be added.

No more I/O port val-
ues can be added.

No more values are avail-
able for the resource you are
trying to add or modify.

The maximum number of values for each
resource is as follows:

4 DMA channels

7 IRQ lines

9 memory address blocks

20 I/O ports

To free values for the resource you are trying to
add or modify, delete some of the values listed
in the resource box for the card. If your card
requires all of the values listed, contact your
card manufacturer to resolve the issue.

Table B-1. Configuration Utility Messages

(Continued)

Message

Probable Cause

Corrective Action

NOTE: For the full name of an abbreviation or acronym used in this table, see the Glossary in the online System User’s Guide.

Advertising