Warning Messages

A warning message alerts you to a possible problem and prompts you to respond before the system continues a task. For example, before you format a
diskette, a message will warn you that you may lose all data on the diskette. Warning messages usually interrupt the task and require you to respond by
typing y (yes) or n (no).

 

Diagnostics Messages

When you run system diagnostics, an error message may result. Diagnostic error messages are not covered in this section. Record the message on a copy of
the Diagnostics Checklist in "Getting Help," and then follow the instructions in that section for obtaining technical assistance.

 

Code

 

Cause

 

Corrective Action

1-1-2

CPU register test failure

See "

Troubleshooting the Processors

" in "Troubleshooting Your System."

1-1-3

CMOS write/read failure; faulty system board

Faulty system board. See "

Getting Help

."

1-1-4

BIOS error

Reflash the BIOS.

1-2-1

Programmable interval-timer failure; faulty system
board

Faulty system board. See "

Getting Help

."

1-2-2

DMA initialization failure

See "

Troubleshooting System Memory

" in "Troubleshooting Your System."

1-2-3

DMA page register write/read failure

1-3-1

Main-memory refresh verification failure

1-3-2

No memory installed

1-3-3

Chip or data line failure in the first 64 KB of main 
memory

1-3-4

Odd/even logic failure in the first 64 KB of main 
memory

1-4-1

Address line failure in the first 64 KB of main 
memory

1-4-2

Parity failure in the first 64 KB of main memory

1-4-3

Fail-safe timer test failure

1-4-4

Software NMI port test failure

2-1-1
through
2-4-4

Bit failure in the first 64 KB of main memory

3-1-1

Slave DMA-register failure

Faulty system board. See "

Getting Help

."

3-1-2

Master DMA-register failure

3-1-3

Master interrupt-mask register failure

3-1-4

Slave interrupt-mask register failure

3-2-2

Interrupt vector loading failure

3-2-4

Keyboard-controller test failure

3-3-1

CMOS failure

3-3-2

System configuration check failure

3-3-3

Keyboard controller not detected

3-3-4

Video memory test failure

3-4-1

Screen initialization failure

3-4-2

Screen-retrace test failure

3-4-3

Video ROM search failure

4-2-1

No timer tick

Faulty system board. See "

Getting Help

."

 

4-2-2

Shutdown test failure

4-2-3

Gate A20 failure

4-2-4

Unexpected interrupt in protected mode

See "

Troubleshooting Expansion Cards

" in "Troubleshooting Your System."

4-3-1

Improperly installed or faulty memory modules

See "

Troubleshooting System Memory

" in "Troubleshooting Your System."

4-3-2

No memory modules installed in the first memory
module connector

Install a memory module in the first memory module connector. See "

System Memory

" in

"Installing System Components."

4-3-3

Faulty system board

Faulty system board. See "

Getting Help

."

4-3-4

Time-of-day clock stopped

See "

Troubleshooting System Memory

" in "Troubleshooting Your System." If the problem

persists, see "

Getting Help

."

4-4-1

Super I/O chip failure; faulty system board

Faulty system board. See "

Getting Help

."

4-4-4

Cache test failure; faulty processor

See "

Troubleshooting the Processors

" in "Troubleshooting Your System."