2. BI-PARTING LATCH GATE DETAILS

The Bi-Parting Latch Gate is typically used in low traffic residential sites due to its ease of use and
added security of magnetic locking. The Bi-Parting Latch configuration can consist of any combination
of models SL 1000-B1 (slide gate), SW 2000-B1 (swing gate) and BG 3000-B1 (barrier gate).

STREET

COMPLEX

Gate

Operator

Master

Gate

Operator

Slave

Exit Loop

Inside Interrupt

Loop

Shadow Loop

Outside Interrupt

Loop

Fence

Fence

INPUTS:

Radio

Cycle

Interrupt Bar

Fire

MagLock

Manual

Inputs

SWITCH S1

SETTINGS:

Slide: Unit

Option

Timer: Sys.

Option

Retry: Sys.

Option

ATG: Sys.

Option

Master: ON

Trap: OFF

SWITCH S1

SETTINGS:

Slide: Unit

Option

Timer: OFF

Retry: OFF

ATG: OFF

Master: OFF

Trap: OFF

1204F21

Master/Slave Cable

Connect MagLock to one unit only.

For safety, setting MUST

be the same for both units.

Figure 17. Typical Bi-Parting Latch Gate Installation

HOW IT WORKS:
• The Master moves first during opening and Slave first during closing, with a 2 second delay

between them to prevent gate intercollision and to ensure proper latching. When the gates are fully
closed, the outer edge of the Master gate rests on the outer edge of the Slave.

• A fault in one unit affects both units (see Troubleshooting/Maintenance for Fault List).
• A continuous FIRE input in either gate opens the gates and holds them open.
There are 3 different ways to close the gates (entering or exiting):
1. Reclose Timer: When the Reclose Timer expires, gates close automatically.
2. ATG and Interrupt Loop: With ATG ON, clearing the Inside Interrupt Loop closes the gates.
3. Alternate Action:

With ATG and TIMER OFF, RADIO or CYCLE commands close fully open gates.

WARNING: The Power Fail Operation Option can be used ONLY on the Master Unit. To maintain all

gate functions during power outages, use a full UPS (Uninterruptable Power Supply) on each unit.

INPUT CONNECTIONS: (for more details, refer to paragraph L, Connecting Input Wiring)
• Inputs can be connected to either gate. For enhanced safety, the Interrupt Bar, Interrupt Loop, and

Shadow Loop inputs may be connected to both gates.

MASTER UNIT SWITCH S1 SETTINGS AND INPUTS

Gate

Type

SLIDE

ACTION

(Reclose)

TIMER

RETRY

ATG

MASTER

TRAP

Operator

Inputs

Bi-Parting

Latch

Unit

Optiono

System

Optionn

System

Optionn

System

Optionn

ON OFF

Systemp

SLAVE UNIT SWITCH S1 SETTINGS AND INPUTS

Bi-Parting

Latch

Unit

Optiono

System

Optionn

System

Optionn

System

Optionn

OFF OFF

Systemp

n

:

Select ATG, Timer and/or Retry from the Master unit and set Slave ATG, Timer and Retry to OFF. Otherwise, the
ATG ON/shorter Reclose Timer/Retry ON in either unit supersedes the other.

o

:

For safe and reliable operation, this setting MUST be the same for both units (see Appendix A).

p

:

Inputs to one unit affect both gate operators, so you can connect inputs to either unit.