Chamberlain Swing GATE User Manual

Page 47

Advertising
background image

46 of 53

Doc 6001242 (01-20273)

Rev C

SHADOW LOOP Activation prevents the gate from opening or closing so the gate won't hit a

vehicle. If the gate is already moving, or if the gate is not fully opened or
closed, this input has no effect.

INSIDE/OUTSIDE INTERRUPT LOOP DETECTOR (TB16)

INSIDE
INTERRUPT LOOP with SLIDE "OFF" and ATG "ON"

Gate fully open or closed: activation prevents the gate from moving.
When the Interrupt loop clears, the gate begins closing.
Gate opening or closing: activation halts the gate. When the Interrupt
Loop clears, an opening gate closes and a closing gate resumes its course.

INSIDE
INTERRUPT LOOP with SLIDE "OFF" and ATG "OFF"

Gate fully open or closed: activation prevents the gate from moving.
Gate opening or closing: activation halts the gate. When the Interrupt
Loop clears, the gate resumes its course.

INSIDE
INTERRUPT LOOP with SLIDE "ON" and ATG "ON"

Gate fully open or closed: activation prevents the gate from closing.
When the Interrupt loop clears, the gate begins closing.
Gate opening or closing: activation halts a closing gate. When the
Interrupt Loop clears, an opening gate closes and a closing gate resumes its
course.

INSIDE
INTERRUPT LOOP with SLIDE "ON" and ATG "OFF"

Gate fully open or closed: activation prevents the gate from closing only.
Gate opening or closing: activation fully opens a closing gate and starts
the Reclose Timer if timer is "ON".

OUTSIDE
INTERRUPT LOOP with ATG "OFF"

Gate fully open or closed: activation prevents the gate from closing only.
Gate opening or closing: activation fully opens the closing gate and starts
the Reclose Timer if timer is "ON".

OUTSIDE
INTERRUPT LOOP with ATG "ON"

Gate fully open or closed: activation prevents the gate from closing only.
Gate opening or closing: activation prevents the gate from closing. When
the interrupt loop clears, the gate begins closing.

INTERRUPT BAR INPUTS (TB11)

INTERRUPT BAR Activation fully opens a closing gate and stops an opening gate. If RETRY

is ON, the gate waits 30 seconds, then tries to resume. The gate will re-try
twice before faulting out. If the Interrupt Bar remains active for more than 30
seconds, the gate will not retry.