Adjusting scanning pause time, Adjusting frequency step and detection mode, Delay – Sony ICF-SC1 User Manual

Page 16: To cancel delay, To cancel the 5-second pause mode, Notes, Adjusting the frequency step, Adjusting the detection mode, Adjusting the frequency step 1

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Adjusting scanning pause

time

Adjusting frequency step and
detection mode

DELAY

DELAY is turned on bv debuilt.

DELAY is indicated in the displace and scanning will not

restart unless there is a reception break of 2 seconds.
This is convenient, for example, when receiving a 2-\va\

transmission, where there is a short break between the
transmission.

To cancel DELAY
Press PRI/DELAY for 1 second or longer.

DELAY will

disappear, and the receiver resumes scanning the moment
signal reception is broken during scanning pause.

Press PRI/DELAY for 1 second or longer again to turn
DELAY on again.

Limiting scanning pause to 5 seconds
(5-second pause mode)

1

If you are in the Scanning Mode, press SCAN to enter

the Manual Mode ( Rifilici disappears).

2

Press SCAN for 1 second or longer.

will be displayed and the decimal point of the

frequency display will flash.

page

I

/ШЯ

DELAY

5k

~ir ППГ

AM

СЖЧ-(3 MHz

___* -__________________

Normally, the receiver will remain in scanning pause until
signal reception is broken or scanning is resumed
manually.
In the 5-second pause mode, the receiver will pause
scanning only for 5 seconds and automatically resume
scanning at every stop.

To cancel the 5-second pause

mode

Press SCAN to return to the Manual Mode. Then press

SCAN lightly (less than 1 second) to re-enter the Scanning
Mode.

Notes

•You can run Programmable Scanning in the 5-second pause

mode by pressing SCAN for 1 second or longer while holding
down b'NTFR,

•DELAY and the 5-second pause can be set indi\'iduallv.
•If the signal breaks in less than 5 seconds, the recei\ er resumes

scanning in 2 seconds (with DELA't' on' or at that moment (with
DELAY off).

•If the signal is recei\'ed for 5 seconds in the 5-second pause

mode, the receiver will resume scanning at that moment
regardless of the DELAY setting.

•To run Service Scanning in the 5-seumd pause mode, see

"Service Scanning", page 17.

30

You can adjust the frequenev step and the detection mode
when you are in the Manual Mode.

Adjusting the frequency step

1

If vou .ire in the Sc.inning Mode, press SCAN to enter

the Manual Mode.

2

Press STEP.

With e.ieh press, the frequenev step changes as
folknvs,

■ AM, NFM:

p 5/(

10k -> 12.5k -> 25k -»• 50k

100k-^

WFM:

50k-* 100k

L

Adjusting the detection mode

1

If you are in the Scanning Mode, press SCAN to enter

the manual mode.

2

Press MODE.

With each press, the detection mode changes as
follows.

c

AM

-

NFM

-

WFM

1

Notes

•You cannot adjust the frequency step and the detection mode

when you are in the Scanning Mode.

•The changes vou have made in frequenev step or detection mode

are effective only in the current band. When you switch to a
different band, the frequency step and detection mode wall

return to default (see "Frequency range of the bands", page 10).

•If the current frequency is not a step frequency when you change

the frequency step, the frequency wall automatically change to a
step frequenev.

•If you have changed the detection mode to WFM w'hen you are

in AM or NFM with the frequency step set to 25 kHz or less, the
frequency step will automatically change to 50 kHz. If the
current frequency is not a step frequency, it will automatically
change to a step frequency.

31

Advertising