Receiving in the Scanning Mode

Band Scanning

The receiver divides its frequency range (25.0 MHz to
1300.0 MHz) into 17 bands. Band Scanning scans one of
these bands step by step.

1

Set the SQL control to MIN.

2

Press POWER to turn the receiver on.

3

Turn VOL to adjust the volume.

4

Press BAND repeatedly to choose a band.

With each press, the lowest frequency of the next
band will be displayed. Press repeatedly until the
display shows the lowest frequency of the band of
your choice.

page

1

/3B3g

DELAY

5k

AM

JIZ nnn

L J.LIUU MHz

Frequency range
(MHz)

step

Detection Mode

25.0 ~ 29.0

5kHz

AM

29.0 ~ 54.0

5kHz

NFM

54.0 ~ 72.0

50kHz -

WFM

72.0 ~ 76.0

5kHz

NFM

76.0 - 88.0

50kHz

WFM

88.0 ~ 108.0

lOOkHz

WFM

108.0 - 137.0

12.5kHz

AM

137.0 -148.0

5kHz

NFM

148.0 ~ 174.0

5kHz

NFM

174.0-216.0

50kHz

WFM

216.0 - 225.0

5kHz

NFM

225.0 ~ 400.0

12.5kHz

AM

400.0 - 470.0

12.5kHz

NFM

470.0-512.0

12.5kHz

NFM

512.0 - 806.0

50kHz

WFM

806.0 - 1000.0

12.5kHz

NFM

(excluding cellular phone band)

1000.0 - 1300.0

12.5kHz

NFM

Modulation. WFM: Wide Band Frequency Modulation)

5

Adjust the SQL control (see page 11).

Scanning will start.
When the receiver receives a signal,

fclita'i

will light

up and the receiver will go into scanning pause. When
the signal breaks off, the receiver will resume
scanning automatically.

To turn off the power

Press POWER.

Frequency range of the bands

10

Note

The frequency steps and the detection modes in the list are the
default for each band. You can adjust the frequency step and the
detection mode when you are in Manual Mode. You cannot adjust
them when you are in Scanning Mode.

To resume scanning manually during scanning

pause

Press + or -.

To change scanning direction

Press + or -.
Scanning will restart in ascending direction if you press +,

and in descending direction if you press -.

Note

When you start scanning a new band, scanning will always start in
ascending direction.

To exit Scanning Mode

Press SCAN.

KithWl

will disappear from the display and the receiver

enters the Manual Mode. Press again to re-enter the
Scanning Mode.
If you press SCAN for 1 second or longer, the scanning

pause time will go into the 5-second pause mode (see
page 30).

Adjusting the SQL control

Adjustment of the SQL control applies to all modes of
reception.

What the SQL control does

The SQL (squelch) control adjusts the threshold of the
signal intensity that opens the squelch.
When the receiver receives a signal above the threshold,

the squelch will open,

i:wta

will appear in the display,

and you will hear the transmission sound.
When the squelch opens during scanning, the receiver

stops scanning. This is called a "scanning pause".

As you turn the SQL control counterclockwise to MIN, the
receiver will pause scanning on weaker signals. But this
may cause the receiver to pause scanning on unwanted
noise signals.
As you turn the SQL control clockwise to MAX, the

receiver will cut off the weaker signals and receive only
stronger signals. If it is turned too far clockwise, on the
other hand, there may be no signal strong enough to cause
a scanning pause.

Adjusting the SQL control

Start from the MIN position and turn it
clockwise towards MAX to the point the miM’i

indication disappears in the display.

When there is a signal above the squelch threshold,
will light up and the receiver pauses scanning. Scanning
will resume automatically when the signal breaks off.

11