Mixer kettle operation using cal 9900, Changing functions & options, Cleveland range factory settings – Cleveland Range (T) MKDL-125-T (-CC) User Manual

Page 13

Advertising
background image

CAL 9900 Controls Drawing

MIXER KETTLE OPERATION
USING CAL 9900

Note: Temperature probe on mixer bridge must
be covered with a minimum of three inches of
product to function correctly.

5.

Push (

*

) button on CAL 9900 to read set point

temperature. (This is the desired product
temperature).

6.

To change set point temperature push and
hold (

*

) button while pushing (

) or (

)

button. New set point is determined when
(

*

) button is released.

7.

Add product to kettle.

8. Turn ACTIVE/BYPASS switch to

“ACTIVE”. If the set point
temperature is higher than the

product temperature, the kettle will start heating.

Note: For twin kettles, the CAL 9900 will control
the kettle the mixer is in.

Changing Functions & Options

The controller has been preset at the factory and should
operate satisfactory. If you wish to fine tune the unit for
your specific application consult the CAL 990O
Installation and Operation Manual. Following is a
simplified procedure for changing parameters.

BYPASS ACTIVE

BYPASS ACTIVE

HEAT AUTO COOL

OFF

OFF ON

1. Open STEAM VALVE completely

2. Turn mixer MAIN POWER switch to

"ON" (CAL 9900 lights up and
displays present temperatures).

3. Turn HEAT/COOL switch to

“OFF/AUTO".

4. Turn ACTIVE/BYPASS switch to

"BYPASS". The unit should not be
heating or cooling at this point.

CAL 9900

˚C

*

p

Process
Temperature
or Set Point

SP1

SP2

Hi

Sp

Lo

*

*

*

Decrease

Increase

View Set Point

Error

CAL 9900

˚C

p

*

CAL 9900

˚C

p

*

CAL 9900

˚C

p

*

CAL 9900

˚C

p

*

CAL 9900

˚C

p

*

CAL 9900

˚C

p

*

BYPASS ACTIVE

OFF ON

Cleveland

Range

Factory

Settings

OPERATING FUNCTION

MODE

NUMBER

0

0

0

1

5

2

0

3

4 steam

4

5 electric

0

5

5

6

0

7

0

8

1

9

0

10

0

11

0

12

0

13

0

14

0

15

9

16

0

17

0

18

1

19

2 T.A.P

20

0

0

21

0 = °C

22

1 = °F

6

23

-- --

24

0

25

-- --

26

1. Mixer MAIN POWER switch in the "ON"

position.

2. ACTIVE/BYPASS switch in "BYPASS" position.

3. Press button labeled (p). The display should show a

number with a decimal place in it.

Left of the decimal
place is the
OPERATING MODE
setting (this number
should be flashing).

To the right is the
FUNCTION NUMBER.

4. To change the

OPERATING MODE
setting push the
(

) or (

)

buttons.

5. To move to the

FUNCTION NUMBER
(right of the
decimal) push
(

*

) button.

6. That number

should now be
flashing. To move
to another FUNCTION
NUMBER
push the
(

) or (

)

buttons.

7. Push (

*

) button to

move to the left of the
decimal. To change
the OPERATING MODE
setting push the
(

) or (

)

buttons.

8. When your changes

are complete push
the button labeled
(p) again to return
to the Process
Temperature.

Advertising