Cleveland Range (T) MKDL-125-T (-CC) User Manual

Page 14

Advertising
background image

MRC 7000 Controls Drawing (1 pen)

Pen
Display

Pen1 key -
AUTO/MAN

AUTO

MAN

SCROLL Key

UP Key

DOWN Key

˚C

˚F

˚U

SP

MAN

OUT1 OUT2 ALRM

Manual

Heat

Output 1

Cooling

Output 2

Alarm

Setpoint

Minus Sign

˚C
˚F

U

SP

MAN

OUT1 OUT2 ALRM

BYPASS ACTIVE

BYPASS ACTIVE

HEAT AUTO COOL

OFF

BYPASS ACTIVE

HEAT AUTO COOL

OFF

MIXER KETTLE
OPERATION USING
MRC 7000 (1 PEN)

Note: Temperature probe on
mixer bridge must be covered
with a minimum of three inches of
product to function correctly.

1. Turn MAIN POWER switch to

"ON".

2. Turn HEAT/COOL switch to

"OFF/AUTO".

3. Turn ACTIVE/BYPASS switch to

"ACTIVE".

4.

Open steam valve completely.

5. On controller keypad push

and hold key " " or
" " until desired temperature
is set.

6. To start: push scroll key

"

" until "

CtrL" is displayed.

7. Push down key " ".

8. To stop: push scroll key

"

" until "

OFF " is displayed.

9. Push down key " ".

NOTE: For twin kettles, the
MRC 7000 will control the kettle
the mixer is in.

If the unit is used continually it
may be simpler to control the
"

ON/OFF " function with the

following steps:

1. Keep HEAT/COOL switch at

"OFF/AUTO".

2. To stop turn ACTIVE/BYPASS

switch to "BYPASS".

3. To change temperature

setting push and hold key
" " or " " until desired
temperature is set.

4. To start, turn ACTIVE/BYPASS

switch to "ACTIVE".

OFF ON