SBI 100 User Instructions Manual

27

6.1 Setup Controls

6.2 Parameters and Settings

Moves flashing digit

Change flashed digits

Saves data and move down to next

parameter setting

Exits setup mode

Config Menu Avail. Settings Default

Definition

Detailed Setting

P11

0,1,2

2

Units key configuration

0 = kg only
1= lb only
2 = units key active kg and lb

P12

0 - 7

7

Power on zero range
(full scale)

0 = +/- 1%
1 = +/- 2%
2 = +/- 5%
3 = +/- 10%
4 = +/- 20%
5 = +/- 50%
6 = +/- 100%
7 = no limitation

P13

00 - 15

3

Zero button range
(full scale)

(00) = +/- 1% (06) = +/- 20% (12) = + 5%
(01)= +/- 2% (07) = +/-no limit (13) = + 10%
(02)= +/- 3% (08)= + 1% (14) = + 20%
(03)= +/- 4% (09) = + 2% (25) = + no limit
(04) =+/- 5% (10)= + 3%
(05)= +/- 10% (11) = + 4%

P14

0,1,2

0

Signal within power on zero
point range

0 = current weight
1 = calibration zero
2 = power off zero point

Hold

Print

Units

Tare

On/Off

Zero

kg

kg