Calibration
division value

Display division value in different weight unit that can be used

kg lb Lb:oz

(oz)

0.0001kg 0.0001kg 0.0002lb Not

available

0.001kg 0.001kg 0.002lb Not

available

0.01kg 0.01kg 0.02lb 0.5oz

0.1kg 0.1kg 0.2lb 5

oz

1kg 1kg 2lb Not

available

10kg 10kg 20

lb Not

available

0.0002kg 0.0002kg 0.0005

lb Not

available

0.002kg 0.002kg 0.005

lb 0.1

oz

0.02kg 0.02kg 0.05

lb 1

oz

0.2kg 0.2kg 0.5

lb Not

available

2kg 2kg 5

lb Not

available

20kg 20kg 50

lb Not

available

0.0005kg 0.0005kg 0.001

lb Not

available

0.005kg 0.005kg 0.01

lb 0.2

oz

0.05kg 0.05kg 0.1

lb 2oz

0.5kg 0.5kg 1

lb

Not

available

5kg 5kg 10

lb Not

available

50kg

50kg

Not available

Not available

Table4: Lb calibration unit:

Calibration
division value

Display division value in different weight unit that can be used

kg lb Lb:oz

(oz)

0.0001lb Not

available

0.0001lb Not

available

0.001 lb

0.0005 kg

0.001 lb

Not available

0.01 lb

0.005 kg

0.01 lb

0.2 oz

0.1 lb

0.05 kg

0.1 lb

2 oz

1 lb

0.5 kg

1 lb

Not available

10 lb

5 kg

10 lb

Not available

0.0002 lb

0.0001 kg

0.0002 lb

Not available

0.002 lb

0.001 kg

0.002 lb

Not available

0.02 lb

0.01 kg

0.02 lb

0.5 oz

15

0.2 lb

0.1 kg

0.2 lb

5 oz

2 lb

1 kg

2 lb

Not available

20 lb

10 kg

20 lb

Not available

0.0005 lb

0.0002 kg

0.0005 lb

Not available

0.005 lb

0.002 kg

0.005 lb

0.1 oz

0.05 lb

0.02 kg

0.05 lb

1 oz

0.5 lb

0.2 kg

0.5 lb

Not available

5 lb

2 kg

5 lb

Not available

50 lb

20 kg

50 lb

Not available

5.11) P11.x: select the weighing unit that may be chosen by pressing UNIT

x = 0 : only kg
x = 1 : only lb
x = 2 : only lb: oz
x = 3 : kg or lb
x = 4 : kg or lb: oz
x = 5 : lb or lb: oz
x = 6 : kg, lb, or lb: oz
Above setting of units may not be available as per above tables in 5.10

5.12) P12.x: Power-on zero-point range

x = 0 : calibration zero point (CAL.P0) +1%FS
x = 1 : calibration zero point (CAL.P0) +2%FS
x = 2 : calibration zero point (CAL.P0) +5%FS
x = 3 : calibration zero point (CAL.P0) +10%FS
x = 4 : calibration zero point (CAL.P0) +20%FS
x = 5 : calibration zero point (CAL.P0) +50%FS
x = 6 : calibration zero point (CAL.P0) +100%FS
x = 7 : No limitation

5.13) P13.x: Zero range for ZERO button after switch on

x = 0 : Power-on zero-point ±1%FS;

x = 1 : Power-on zero-point ±2FS;
x = 2 : Power-on zero-point ±3%FS;
x = 3 : Power-on zero-point ±4%FS;
x = 4 : Power-on zero-point ±5%FS;

Advertising