Flt ext x – Salter Brecknell HS-300 User Manual

Page 5

Advertising
background image

4

(2)

Choose weighing units among kg-lb-lb: oz

Note: The weighing units that can be used are restricted by display
division, and calibration weight unit (restricted by P8, P9, and P10):

For example, if the calibration unit is “kg”; calibration display resolution
is 50kg (that means: P8=5, P9=0, P10=0), and users press UNIT key to
choose weighing units. Lb or lb:oz are not allowed to choose, since the

display resolution of 100lb or 2000oz is not available to this indicator.

(3)


Tare the weight. This function can be activated only when the scale is in

stable mode and the gross weight is not negative value.

(4)


Zero function. When the weight is within zero range, it will active as
ZERO function and clear the tare weight. When the weight is not within

zero setting range (P13 set), the scale will show 0¯ ¯ ¯ ¯

(zero point is over

the setting range), or 0

_ _ _ _

(

zero is below the setting range).

3.2. In normal weighing mode and hold down time longer than 3s:


(1) Same meaning with that in 3.1


(2) Same meaning with that in 3.1


(3) Same meaning with that in 3.1


(4) Power off the scale.

UNIT

TARE

ZERO

HOLD

PRINT

UNIT

TARE

OFF

HOLD

PRINT

UNIT

TARE

OFF

5


(5) +

Hold these two buttons to show firmware version; A/D code or input

working voltage of indicator.


(6) +

Hold these two buttons to enter setting mode when the sealed calibration

switch

is

on.

(7) +

Hold these two buttons to enter calibration mode when the sealed

calibration switch is on.

3.3 In setting mode:


HOLD

UNITS TARE

OFF/ON


(1)

Rotate the flashed position from right to left


(2)

Change the digit on flashed position. The digit can be changed
to 0, 1, 2…9; and be flashed.

(3)

Confirm receiving and storing the displayed parameters,
After the setting of the last parameter, the indicator will
not exit the setup mode, and cycles from the first parameters
for viewing or modifications.

(4)

Exit from setting mode to normal work mode


3.4 In displaying A/D code or input voltage mode:


(1)

No function

OFF

HOLD

PRINT

OFF

UNIT

OFF

TARE

X

WT

VOL

FLT

EXT

X

Advertising