24

. The meaning of some displayed symbols:
1. 0¯ ¯ ¯ ¯

----------

zero point is over the setting range

2. 0

_ _ _ _

----------

zero is below the setting range

3. Ad¯ ¯ ¯

----------

ADC is over max. range;

4. Ad

_ _ _

--------- ADC is below min. range;

5. ¯ ¯ ¯ ¯ ¯ ---------- weight signal is too large
6. _ _ _ _ _ ------- weight signal is too small
7. EEP.E0 -------- the EEPROM can’t be accessed;
8. EEP.E1---------The parameters are not same with backup data;
9. EEP.E2---------The setting parameter(s) is not in normal range;.
10. CAL-Px --------scale’s calibration point;
11. CAL.Er ---------there is an error in calibration
12.  Hold ----------hold function is active.
13. Net ◄----------- The display reading is net weight
14. Zero ◄----------The scale is at zero point
15. CAP.-- -----------The the setting full capacity will be displayed
16. d.-- -----------The division will be displayed

17. Px.y ----------- The No. x parameter is set to y.

18. Lo.bAt ----------The voltage of batteries or input power is below 4.7V

. The direction of indicator with bracket

The display is supplied with ABS plastic bracket, wall mounting vertically or
bench mounting horizontally to read the weight display as following drawings.









(1) Placed vertically (2) Placed horizontally

25

.Key Definition summary:

KEY MODE

DEFINITION

HOLD

/PRINT

Normal weighing mode

Enter or exit HOLD mode; output the
data as per P4,P5,P6 setting

Setup mode/Calibration

mode

Shift the flashed position from right to
left

Displaying A/D code or

input voltage mode

No Function

UNIT

Normal weighing mode

Choose weight units, refer P8, P9,
P10, P11 setting and Table3,Table4.

Setup mode/Calibration

mode

Change the digit on flashed position
and click this button to add 1.

Displaying A/D code or

input voltage mode

Choose the weight inner code or input
working voltage to be displayed.

TARE

Normal weighing mode Tare the weight

Setup mode/Calibration

mode

Confirm the displayed parameters or
input data, and go to next step

Displaying A/D code or

input voltage mode

Choose filtered or un-filtered weight
A/D data

ON/OFF/

ZERO

Normal weighing mode Zero function or Power off the scale.

Setup mode/Calibration

mode/Displaying A/D code

or input voltage mode

Exit and back to normal work mode

ON/OFF/

ZERO

+

HOLD

/PRINT

Normal weighing mode

(more than 3s)

Go to Show A/D code or input
working voltage of indicator mode

Advertising