28

11=Power-on zero-point +4%FS
12=Power-on zero-point +5%FS
13=Power-on zero-point +10%FS
14=Power-on zero-point +20%FS

P14.x

0, 1, 2

2

Weight signal within power-on zero
point range, Choose which data as
current power-on zero point; 0= current
weight ; 1= calibration zero-point;
2=switch-off zero-point

P15.x

0, 1, 2

1

Weight signal not within power-on zero
point range, Choose which data as
current power-on zero point; 0=
current weight ; 1= calibration
zero-point; 2=switch-off zero-point;
3=continuously display “0ˉˉˉˉ”

P16.x

0, 1, 2, 3,

4, 5, 6,7,8

8

Zero tracking range: 0=0d, no tracking;
1=+0.25d; 2= +0.5d; 3=+1d; 4=+1.5d;
5=+2d; 6=+3d; 7= +4d; 8=+5d

P17.x

0, 1, 2, 3

2

Data filter intensity: 0=very weak,
1=weak, 2=middle, 3=strong

P18.x

0, 1….9

1

Check weight stability range: 0=+0.5d;
1= ± 1d ; 2=+1.5d; 3=+2d; 4=+3d;
5=+4d ; 6=+5d ; 7=+6d ; 8=+7d; 9=+8d

P19.x

0, 1….9

1

Overload limit range: 0=FS+0d;
1=FS+9d; 2=101%FS; 3=102%FS;
4=105%FS; 5=110%FS; 6=120%FS;
7=150%FS; 8=200%FS; 9=No limitation

P20.x 0,1,2

2

Backlight on-off mode:
0= Backlight is always off;
1= Backlight is always on;
2= Backlight is auto on and auto off. It is
auto off after 10s when scale goes to
stable and has no key operation, and it is
auto on when scale is unstable or there’s
some key operation.



29