16 troubleshooting, 1 safety notices, 2 cause and action – CASO Germany VC 12 Vacuum Set User Manual

Page 44: Attention

Advertising
background image

caso Vakuumierer VC12

44

Please open the adapter and clean it with warm
water.


Opened adapter

Wipe off the adapter with a soft cloth and put it
together again afterwards.

16 Troubleshooting

This chapter provides you with important notices with regard to operating the device.
Observe the following notices to avoid dangers and damages:

16.1 Safety notices

Attention

► Only qualified electricians, who have been trained by the manufacturer, may carry out

any repairs on electrical equipment.

► Improperly performed repairs can cause considerable dangers for the user and

damages to the device.

16.2 Cause and Action

In the event of a fault, an error code will appear in the display; it describes the cause of the
fault.

Error

Possible cause

Rectification

Vacuum unit is not
functioning

Power plug is not plugged
in

► Plug in mains plug!

Defective power cable or
plug

► Send device to Customer

Service

Defective electrical socket

► Select another electrical socket

The first weld on the cut
off piece of the roll is not
being carried out.

Roll is not positioned
correctly

► Follow the steps in the chapter

“Vacuum packaging in a bag
originating on the roll”

A complete vacuum is
not being created in the
bag.

The open end of the bag is
not completely inside the
vacuum chamber

► Position the bag correctly

The bag is defective

► Select another bag

There is dirt on the
welding and the normal
seals

► Clean the seals and retry

correctly once they are dry

The bag is not being
welded correctly

The welding bar is
overheating so that the bag
melts

► Open the cover on the unit and

let it cool down for a few
minutes

Advertising