Probable Cause

Problem

Action

When unit is armed, red LED flashes

twice, green LED is on for 15

seconds, but the unit does not give

three beeps after the green LED

goes off.

The actuator is sticking to

the micro switch.

Call Detex.

1-800-729-3839

No LED activity when key is turned

ccw to armed position.

Dead or weak battery.

Battery not secured to

connector correctly.

Battery connector or wires

damaged.

No AC power.

Install new battery, LED's should

flash and the siren beep once.

Secure battery correctly.

Call Detex.

1-800-729-3839

Verify power from transformer and

check for correct voltage at

connector P2.

AC powered unit gives a low

battery indication.

Install battery.

If battery is not desired, disconnect

power and slide the 'Dis Lo Bat IND'

switch to 'ON' position.

Battery not installed.

OR

Low battery

LED's do not flash to indicate

armed or disarmed status.

Status indicator switch in off

position.

Remove power from unit. Slide

'Status indicator' switch to 'ON'

position. Reinstall power.