Delayed egress operations, Battery backup for alarm, Low battery indication – Detex V40 EE User Manual

Page 13

Advertising
background image

Turn Key CW To Disarm

Glowing Green LED

Red LED while alarming

EXITING UNDER ALARM

ARMING AND AUTHORIZED EXIT

Turn Key CCW To Arm

DISARMING

For BENCH TESTING:

push and hold deadlatch while

performing alarm test operations

Deadlatch

(LHR shown)

Red LED

Green LED

Cylinder

Mortise

PushPad

Siren

Home Key

Position

NORMAL OPERATION

NUISANCE DELAY

With door closed, insert key in the cylinder, turn CCW then back to the home key position and remove it.

The red LED blinks twice then the green LED glows continuously. Authorized personnel can exit the

door during this rearm cycle. After a 1, 5 or 15 second arming period, the alarm issues three quick

beeps and the green LED goes off, indicating that the unit is armed.

Insert key, turn CW to a stop. Green LED will blink twice to indicate the unit is disarmed.

To exit, push and maintain pressure on the pushpad. After a one-second delay, (nuisance delay), LED

flashes RED and alarm pulses on and off for 15 seconds. After 15 seconds, alarm issues short and

long pulses to indicate that you can exit by depressing the pushpad. Alarm sounds continuously and LED

is steady RED. Turn key CW to stop alarm.

When pushpad is depressed for less than 1

second, alarm will emit a single pulse but

will not start delay function.

DELAYED EGRESS OPERATIONS

Indicates the unit is in process of arming. The siren will chirp three times to indicate the unit

is armed and green LED will turn off

DOUBLE BLINK

DOUBLE CHIRP

OFF

Low Battery - every 45 seconds

LED COLOR

SLOW BLINKING

FAST BLINKING

ON

ON

OFF

RED
OFF

Pushpad is depressed, delay to open started

This indicates either armed or disarmed

Delay to open expired
Delay to open expired, door has been opened

ON

SLOW PULSE

FAST PULSE

OFF

OFF

OFF

ON

OFF

SIREN SOUNDS

THREE CHIRPS

GREEN

ON

FUNCTION

Factory installed jumper removed from 3 & 4 terminals

BLINK

BLINK

OFF

OFF

Armed - status ON

Disarmed - status ON

BATTERY BACKUP FOR ALARM

A 9-volt battery is included as a backup power source for the alarm siren if power is lost.

To disable low battery indication, slide the DisLoBat switch to 'ON'. See page 16 for location.

LOW BATTERY INDICATION

If battery voltage is low(7 volts or less), unit remains armed but LED flashes RED and unit beeps

twice every 45 seconds. Replace battery as soon as possible.

103185 Page 13