Detex EA-2500 User Manual

Page 2

Advertising
background image

NOTE TO THE INSTALLER

DETEX INS2500 PAGE 2

OTHER ITEMS REQUIRED

Rim cylinder, 5, 6 or 7-pin.

A 5-pin cylinder is available from

Detex as part number ECL-445K

- For 6-pin or 7-pin cylinder, a

spacer is required (Detex part #

ECL-1595)

Transformer, 12 VAC, 25VA

Detex part number PP-5152-3

For international applications at

240 VAC, use

Detex p/n PP-5452-2

Magnetic switch, Form "C" switch

Detex p/n MS-2049

MOUNTING SCREWS

Two types of screw are supplied

with the EA-2500; #10-32 machine

screws and #10 thread-forming

screws.The machine screws are re-

quired for installing the flush unit

and the thread-forming screws are

for the surface unit.

TOOLS AND SUPPLIES

REQUIRED

Screwdriver, blade type, 5/16"

Screwdriver, blade type, 1/8"

Screwdriver, Philips, #1

Linesman's pliers to cut the cylin-

der tailpiece.

Drill motor and bits

Punch for knockouts

Hammer

Pencil

Hole saw

ALARM BY-PASS

(EXTENDED)

When it is necessary to by-pass the

alarm for extended periods of time,

such as when deliveries are being

made through a protected door, an

adjustment is provided in the alarm

for this situation as described on

page 5 Fig. 6.

90 DEGREE DETENT

To prevent removal of the arming

key in the disarmed position, a de-

tent is provided in the hardware kit.

(See page 5 Fig. 6)

ALARM BY-PASS

AUTO-REARM

With this feature, the unit will sound

when the door is opened by unau-

thorized personnel, stop when the

door is closed and automatically

rearm the alarm. (See page 5 Fig. 6)

NOTE

These instructions cover the surface

mounted EA-2500S and the flush-

mounted unit, EA-2500F. Many of

the steps involved in installing this

product are common to both units.

When a step applies to a specific

unit, that information is so noted.

Insert the faceplate lock key in the

faceplate lock cylinder and turn it

about eight turns counter-clockwise

until the cylinder releases the inter-

nal locking stud.

The bottom edge of the faceplate is

held captive by an internal retainer.

Push the bottom edge upward to

release it.

Turn the IKC key maximum counter-

clockwise (Switch Lever released).

The "LED" will be turned off. The

door may be opened & closed dur-

ing this time without the unit sound-

ing. Once the "LED" turns back

"ON" the unit will sound instantly

when opening the door and con-

tinue to sound until the unit is re-set

with the key.

ARMING

(See page 5 Fig. 8)

Install the internal key control

(IKC)

These instructions contain informa-

tion required by the owner. Please

turn them over to the owner when

the installation is complete.

FEATURES

The EA-2500 Exit Alarm includes

the following features.

COMMUNICATIONS TO A

REMOTE INDICATING

PANEL (RIP)

When the system is armed and a

protected door is opened, a signal is

sent to the RIP. (Optional)

REMOTE BY-PASS

By installing an optional remote by-

pass switch, (Detex part # CS-915A),

authorized personnel can enter with-

out setting off the alarm.

N/O Dry Contact.

MULTIPLE DOORS

Several doors can be monitored with

one alarm. Wiring for multi-door

installations is given on page 5 Figs.

12/13.

CALL BELL

This feature (optional), uses a con-

ventional door bell (N/O Dry

contact)to trigger the alarm in the

EA-2500 (Detex part # EA-803).

ADJUSTABLE TIME DELAY

When the system is by-passed by an

authorized person, that person has a

limited amount of time to exit and

close the door before the alarm

sounds. The time delay is preset at

the factory to approximately 8 sec-

onds (minimum time). If more time

is desired, an adjustment is pro-

vided in the alarm (See page 5 Fig.

6).

Advertising