S-5500 SSG and Captured Corner Mullion Installation Instructions

Section VI: Glazing Preparation (SSG)







INTERMEDIATE HORIZONTAL AT SSG CORNER

Apply two beads of sealant in the

reglets of the corner mullion where

the corner mullion glazing adapter

mates into the corner mullion.

Note: The corner mullion glazing adapter

must be set immediately after this step,

before the sealant begins to cure.

CORNER

MULLIONS

SSG INTERMEDIATE

HORIZONTAL

SSG CORNER

MULLION GLAZING

ADAPTER