EFCO S5500 SSG Captured User Manual
Page 74

EFCO CORPORATION 6/2012
PART NO. Y556
Page 74 of 81
S-5500 SSG and Captured Corner Mullion Installation Instructions
Section XI: Glazed SSG Corners
VERTICAL SPACER
GLAZING TAPE
Setting blocks
located per shop
drawings.
HORIZONTAL PRESET
GLAZING GASKETS
Glazing tape spacer runs
through splice joint
Butt horizontal
glazing gaskets into
the vertical spacers.
VERTICAL SSG AND HORIZONTALLY CAPTURED AT MULLION SPLICE
(WITHOUT MULLION SPLICE SIMILAR)
SSG VERTICAL
MULLION
HORIZONTAL PRESET
GLAZING GASKET
VERTICAL SPACER
GLAZING TAPE
Notch darts on end of
horizontal gaskets.
CAPTURED
HORIZONTAL
MULLION
CAPTURED
HORIZONTAL
MULLION
Customer / Installer Note:
EFCO setting blocks are
typically 4” in length with
different depths. If the
glazing infill is “NOT BY
EFCO” and glazing sizes are
larger than 40 square feet,
the glazing details must be
reviewed by the glazing
manufacturer for proper
glazing block size.