S-5500 SSG and Captured Corner Mullion Installation Instructions
Section XI: Glazed SSG Corners
STEP #1 APPLY SPACERS, SETTING CHAIRS, AND SETTING BLOCKS
A. Install the setting chairs and blocks as required. Refer to the approved shop drawings for
locations.
B. Apply the glazing tape as shown on page 41 in Section VI of this manual. Refer to the approved
shop drawings for part numbers and other job specific information.
Notch darts on end
of horizontal
spacers.
HORIZONTAL PRESET
SPACER GASKETS
Butt horizontal
spacers into the
vertical spacers.
SSG HORIZONTAL
MULLION
VERTICAL SPACER
GLAZING TAPE
SSG VERTICAL
MULLION
Setting chair and
blocks located per
shop drawings.
4-SIDED SSG AT MULLION SPLICE
(WITHOUT MULLION SPLICE SIMILAR)
Glazing tape spacer runs
through splice joint.
VERTICAL SPACER
GLAZING TAPE