Setting block locations, Step 2) setting block locations – EFCO 525 Series User Manual

Page 38

Advertising
background image

4483/4484 DOOR HEADER DEAD LOAD

100

90

120
110

40
30

70
60
50

80

10

20

4491 HORIZ. DEAD LOAD

.125 Deflection

Glass Width (in inches)

80

90

100

110

120

30

40

50

60

70

10

20

Glass Height (in inches)

[FIG. 57]

60 70

90

80

[FIG. 56]

1/4 Point

110

100

120

1/8 Point

Glass Height (in inches)

[FIG. 58]

Glass Width (in inches)

.0625 Deflection

90

70

55 60

80

110

100

1/8 Point

120

1/4 Point

SECTION IX - GLAZING

PAGE 36

(CONT.)

Depending on the size and configuration of each DLO, the glass setting

blocks must be placed to give the best support of the glass without adding

dead load weight to deflect the horizontal. Figure 56 below shows typical

1/4 point and 1/8 point setting block locations. Contact EFCO Structural

Engineering for blocking requirements other than 1/4 and 1/8 points.

STEP 2) SETTING BLOCK LOCATIONS

Setting block locations should be determined by following the Dead Load

Charts shown in figures 57 and 58 below. These charts are for general

reference only and refer to laminated glass constructed from (2) 1/4" glass

panes and laminate material. If the glass size you require falls outside the

parameters of these charts or if your glass is not constructed from (2) 1/4"

panes of glass and laminate material, please contact EFCO Structural

Engineering.

525 IMPACT

DLO

4

DLO

4

DLO

8

DLO

4

DLO

4

DLO

8

DPS 1/2004