Glazing pocket identification in verticals, Step 3) glazing pocket identification in verticals – EFCO 525 Series User Manual

Page 39

Advertising
background image

[FIG. 62]

SECTION IX - GLAZING

[FIG. 59]

[FIG. 60]

[FIG. 61]

DPS 1/2004

PAGE 37

(CONT.)

DEEP

4477

4478

DEEP

4480

DEEP

4476

DEEP

SHALLOW

TRANSOM

GLAZING

STOPS

4481

STEP 3) GLAZING POCKET IDENTIFICATION IN

VERTICALS

As instructed in figures 10 and 11 on pages 13 and 14, ensure that each

vertical DLO has at least one DEEP glass pocket on either side. It is

necessary for the glazing installation that a deep pocket be used to load

the glazing units. One exception is the applied transom glazing stops.

The applied stops do not require the glass to be loaded into a deep

pocket. These details are shown with the deep glazing pockets shown

right justified for viewing clarity.

SHALLOW