Fig. 14] [fig. 13, Fig. 13a, Step 8) subsill anchor installation – EFCO 945 Series User Manual

Page 19: Con’t)

Advertising
background image

For standard applications utilize anchorage shown in Figure 13. If

heavy-duty anchorage is required, refer to the location of K473 heavy-duty

anchor as shown in Figure 13A.

[FIG. 14]

[FIG. 13]

(FASTENERS NOT

SUPPLIED BY EFCO)

BAB 11/2000

[FIG. 13A]

SUBSILL

2G22

K473 HD ANCHOR

(OPTIONAL)

8308

STEP 8) SUBSILL ANCHOR INSTALLATION

At a minimum, anchor at 6" from jambs and corners, (1) on each side

of vertical mullions, and 24" O.C. between verticals. These are general

guidelines. Size fasteners as required to meet structural loads.

SECTION V - SUBSILL FABRICATION

(CON’T)

INCLUDES CAPTURED AND STRUCTURAL GLAZED MULLION SYSTEMS

PAGE 17

3" ±

24" O.C.

MAX.

6"

3"±

24" O.C.

MAX.

6"

6"

3/4"