Step 9) subsill anchor seal, Con’t) – EFCO 945 Series User Manual

Page 20

Advertising
background image

[FIG. 15]

[FIG. 16]

STEP 10) SUBSILL PERIMETER SEAL

The subsill interior should be sealed with a silicone type sealant.
Apply sealant and tool the sealant to ensure a good seal. Clean off all

excess sealant. At this time, use a silicone type sealant to seal the

thermal break area as shown in Figure 16. Tool the sealant into the
thermal break area, and ensure that the sealant does not interfere with
the subsill anchor leg notch. See Detail "A."

SILICONE

TYPE

SEALANT

SILICONE

TYPE

SEALANT

SUBSILL

2G22

DETAIL "A"

BAB 11/2000

SUBSILL

ANCHOR

LEG

SUBSILL

2G22

STEP 9) SUBSILL ANCHOR SEAL

The subsill anchor must be sealed with a silicone type sealant. To

ensure a good seal, tool the sealant onto the fastener.

SECTION V - SUBSILL FABRICATION

(CON’T)

INCLUDES CAPTURED AND STRUCTURAL GLAZED MULLION SYSTEMS

SILICONE TYPE SEALANT

PAGE 18

Advertising