Discharging a pb battery, Charging a pb battery – Losi LOSB9606 User Manual
Page 25
Charging a Pb battery
Charging a Pb battery
Battery
type
P b C H A R G E
4.0A 12.0V(6P)
P b - 6 4 . 0 A 12.59V
CHG 022:43 00682
-
Batt type
 Stop
Elapsed
time
+
Charge
current
Battery
voltage
Start
Enter
-
‘>3 seconds’
+
Charged
capacity
Discharging a Pb battery
P b D I S C HARGE
1.0A 12.0V(6P)
-
Batt type
 Stop
+
Start
Enter
-
‘>3 seconds’
+
P b - 6 0 . 4A 12.59V
DSC 022:43 00682
Battery
type
Elapsed
time Discharge
current
Battery
voltage Discharged
capacity
24
Set up the charge current on the left and nominal voltage on the right. 
Range of charge current is 0.1-5.0A, the voltage should match the battery 
being charged. Press and hold the ‘START/ENTER’ key for more than three 
seconds to begin charging.
This screen displays the real-time charging status. Press the ‘START/ENTER’ 
key to change the discharge current. Press the ‘START/ENTER’ key again to 
store the parameter value you set. Press the ‘BATT TYPE/STOP’ key to end 
the program.
Set up the charge current on the left and nominal voltage on the right. 
Range of discharge current is 0.1-5.0A, the voltage should match the 
battery being charged. Press and hold the ‘START/ENTER’ key for more than 
three seconds to begin charging.
This screen displays the real-time discharging status. Press the 
‘START/ENTER’ key to alter discharge current. Press the ‘START/ENTER’ key 
again to store the parameter value you set. Press the ‘BATT TYPE/STOP’ key 
to end the program.