FG-2000 SERIES: INSIDE GLAZE, SCREW SPLINE FRAME ASSEMBLY

MIN. CLEARANCE

5/16" CLEARANCE

MIN. CLEARANCE

1/8" SPACE

7/16"

3/8"

Most of the extrusions in this system are the same,

only the sill and its anchors are different. Notice

also, that the tapes used for sealing the horizontals

to mullions are located in a different manner.

The sill is designed so that the sill anchors may be

cap sealed before the frame is installed. The frame

is installed over the sill twist-in anchors. This pre-

vents any additional screws from penetrating the

sill and causing leaks under the sill.

Multiple units require the use of split mullions. A

minimum of 7/16" clearance between the jamb and

sill end dam must be provided. This will provide a

minimum of 3/8" clearance to move first unit side-

ways to the second unit with the same clearance

will clear interlocking legs of the expansion mull.

Adjust frame locations before running perimeter

seals. Oldcastle BuildingEnvelope recommends using

FG-2188 vinyl filler to improve the perimeter seal.