INSIDE GLAZE SILL FLASHING INSTALLATION

SEAL WITH A NON-SKINNING,

NON-HARDENING SEALANT.

FILL BREAK IN FLASHING

AND SEAL UNDER SPLICE.

FG-2000-FP-8/9

PART #: 7965

1/4" NOM.

SEALANT

FG-2180

FG-2000-FP-2

PART #: 7165

FLASHING ANCHORS MUST

BE CAP SEALED.

FG-2000-FP-1

PART #: 7943

TWIST IN ANCHOR

SHIM UNDER SILL FLASHING

1. ANCHORS DESIGNED TO

TWIST IN.

2. SPACE ANCHORS MAX. 4" FROM

EACH SIDE OF MULLION.

3. BENT LEG ALWAYS TO

EXTERIOR.

4. STAKE ANCHORS TO PREVENT

HORIZONTAL MOVEMENT.

ANCHOR MUST FACE EXTERIOR AS SHOWN.

INTERIOR

NOTE: SILL FLASHING

SHOULD BE LEVEL AND

MAKE SURE IT IS NOT TILTED

TOWARD THE INTERIOR.

SILL SPLICE

F G - 1 0 0 0 - F G - 2 0 0 0 S T O R E F R O N T I N S T A L L A T I O N M A N U A L

Phone: 1-866-OLDCASTLE (653-2278)

Web Address: www.oldcastlebe.com