OUTSIDE GLAZE-SILL INSTALLATION AND PERIMETER SEAL

SHIM UNDER SILL FLASHING

SPACE BETWEEN SILL AND FLASHING (C) TO BE

CONTINUOUSLY SEALED EXCEPT FOR 1/2"-3/4"

SPACE UNDER VERTICAL MULLIONS FOR WEEPAGE.

ONCE THE WALL IS SECURED, SEAL GROVE (D)

BETWEEN SILL FLASHING AND BACK OF SILLS.

THE QUALITY OF THE INSIDE AND OUTSIDE

PERIMETER SEALS (C AND E) MAY BE IMPROVED

BY USING FG-1192/FG-2188 RIGID PVC FILLER.

THE PART MAY BE USED IN FULL LENGTHS OR CUT

INTO PIECES. ITS PURPOSE IS TO PROVIDE

SUPPORT FOR THE BACKER ROD REGARDLESS

OF JOINT OR SIZE. PERIMETER SEAL (F) IS FOR

COSMETIC PURPOSES AND IS OPTIONAL.

E

E

E

E

FG-1122

FG-2122

FG-1000-FP-3 PART #: 7166

FG-2000-FP-3 PART #: 7944

(PARTS SOLD IN

STOCK LENGTHS.)

X 4" LONG

NOTE: 1/2"-3/4" WEEP HOLE

REQUIRED IN SEALANT AT

FLASHING (C) AT CENTER

LINE OF MULLION.

D

C

F

8

FEBRUARY 2012




F L U S H G L A Z E S E R I E S 1 0 0 0 a n d 2 0 0 0 I N S T A L L A T I O N M A N U A L