OUTSIDE GLAZE-FRAME INSTALLATION

FG-1122

FG-2122

(PARTS SOLD IN STOCK LENGTHS.)

1. ASSEMBLY WITHOUT FLASHING

IS NOT RECOMMENDED.

2. DO NOT ANCHOR WALL THRU

VERTICAL LEG OF FLASHING.

SEALANT

ACCESS HOLE AT ALL ANCHOR LOCATIONS.

(SIZE DETERMINED BY ANCHOR.)

DRILL CLEAR HOLE IN FLASHING THROUGH

ANCHOR CLIP. THEN INJECT SEALANT INTO

HOLE IN FLASHING AND UNDER ANCHOR CLIP.

ANCHOR SIZE AND FREQUENCY SHOULD BE DETERMINED BY STRUCTURAL REQUIREMENTS.

SILL ANCHORS FG-1000-FP3/FG-2000-FP-3 AND HEAD ANCHORS FG-1122/FG-2122 SHOULD BE

LOCATED SO THAT THE ANCHOR IS NOT MORE THAN 4" FROM EACH SIDE OF THE MULLION.

FG-1000-FP-3 PART #: 7166

FG-2000-FP-3 PART #: 7944

FG-1192

FG-2188

PVC PROFILE

USED TO IMPROVE

INSTALLATION OF

BACKER ROD AND

PERIMETER SEALANT.

(OPTIONAL)

CLEAR HOLE

(SIZE DETERMINED BY ANCHOR.)

X 4" LONG

7

FEBRUARY 2012




F L U S H G L A Z E S E R I E S 1 0 0 0 a n d 2 0 0 0 I N S T A L L A T I O N M A N U A L