Self Diagnosis Functions

*

Our company provides the thoughtful services for customer,air conditioners had been
installed self diagnosis system to display the information for the units.

INSTALLATION & REPAIR GUIDE

Split Wall-Mounted air conditioner

12

*

According to the service conditions and operating environment , the inside of the air conditioner

will become dirty after several seasons (3 to 5years ) of service , resulting in decreased operating

performance .Inspection and maintenance are recommended in addition to usual cleaning (The

air conditioner can be used for a longer period and without anxiety .)

*

As to inspection and maintenance , consult your dealer or any one of business offices of dealing

companies .(Service charge is required in this case .)

*

We recommend to perform inspection and maintenance during an off seasons.

*

Choose the place where hot air and operation noise from the outlet of the outdoor unit do not annoy

the neighborhood .

*

Things left near the outlet and inlet of the outdoor unit cause malfunction or increased operation

noise . Do not leave obstacles near the outlet and inlet .

*

If irregular sound is heard during operation , consult with your distributor .

*Inspection and Maintenance

Note:Above self check information is commonly applicable in our most air conditioners,but some

are special,you can refer to the User's Manual for information or contact the dealer or authorized

maintenance people for help.

Digital self-check code/
(Polychrome screen self-check code)

Hint to defrosting

Flicker 1 time/1s

Hint to defense

against cold wind

Flicker 1 time/3s

Failure of room

temperature sensor

Failure of coiled

pipe sensor

Abnormality of

outdoor unit

Without feedback of

internal fan motor

Zero crossing signal

without current

External feedback

failure

Overheat protection

Water pump failure

Self-check code of luminotron/
(Self-check code of running lamp)

Flicker 2 times/4s

(Flicker 2 times/8s)

Flicker 3 times/5s

(Flicker 1 time/8s)

Flicker 4 times/6s

(luminating)

Flicker 5 times/7s

(Flicker 6 times/8s)

Flicker 6 times/8s

Flicker 7 times/9s

Flicker 8 times/10s

Flicker 9 times/11s

Self-check
information

Indicates "dF"or defrosting

indicator displays

Fan motor picture not running

E2/(L2)

E3/(L1)

E4/(E5)

E5/(L6)

E7

E6

E8

E9

Advertising