Selection of installation positions for indoor unit*

*

To be installed at the position where the air delivered from the unit can reach every corner of

the room;
*

To avoid being affected by the outdoor air;

*

To avoid blockage to the air inlet or outlet of the unit;

*

To avoid too much oil smoke or steam;

*

To avoid possible generation, inflow, lingering or leakage of flammable gases;

*

To avoid high-frequency facilities (such as high frequency arc welders, etc.);

*

To avoid the places where acid solutions are frequently used;

*

To avoid the places where some special sprayers (sulfides) are frequently used.

*

Not to install a fire alarming device near the air outlet of the unit (during operation, the fire alarm

device might be erroneously triggered by the warm air from the unit);

Above 100mm(4")

Left side: 150mm(6")

and above

Right side: 150mm (6")

and above

Ceiling

Wall hanging plate

ground

2300mm(7'6")

and above

* Make sure of enough space for installation and maintenance.

*

To take into consideration the operational convenience and safety in installation, it is recommended

to ensure enough space between the unit and the walls.

* Height limits of indoor and outdoor units.

*

Either the indoor unit or the outdoor unit can be higher, but the height difference must comply the stated

requirements.
*

Try to reduce the bending of the piping line as much as possible so as to avoid possible negative impacts upon the

performances of the units.

Indoor unit

outdoor

unit

5m(16'5")max.