Installation fixture of outdoor unit

*

Inspections:

a. Check if the hooks at the top and bottom

are firmly fixed.

b. Check if the position of the master unit is

properly leveled.

c. The drain pipe should not curve upward

(Fig.5).

d. The drain pipe should be at the lower part

of the wall pipes (Fig. 5).

Drain pipe

Connecting wires

Connecting pipe

Wall pipe

Drain pipe

Fig.5

*

Try to ship the product to the installation location in its original package;

*

As the gravity center of the unit is not at the installation center, special caution should be taken

when using hoisting cables to lift it up;
*

During shipping, the outdoor unit must not be slanted to over 45 degrees (Do not store the unit

in a horizontal way).
*

Use expansion bolts to fix the mounting supports on the wall;

*

Use bolts and nuts to fix the outdoor unit firmly on the supports and keep on the same level;

*

If the unit is installed on the wall or at the rooftop, the supports have to be firmly fixed so as to

resist earthquake or strong wind.

Dimensions for parallel units installations

300mm(1')min